  • A16-30-10 ABB Contactor 220-230V 50Hz / 230-240V 60Hz
A16-30-10 ABB Contactor 220-230V 50Hz / 230-240V 60Hz

A16-30-10 ABB Contactor 220-230V 50Hz / 230-240V 60Hz

Product Description:

Dimensions


    • Product Net Width:

    • 44 mm


    • Product Net Depth / Length:

    • 74 mm


    • Product Net Height:

    • 74 mm


    • Product Net Weight:

    • 0.34 kg

Technical


    • Number of Main Contacts NO:

    • 3


    • Number of Main Contacts NC:

    • 0


    • Number of Auxiliary Contacts NO:

    • 1


    • Number of Auxiliary Contacts NC:

    • 0


    • Standards:

    • Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1


    • Rated Operational Voltage:

    • Auxiliary Circuit 690 V
      Main Circuit 690 V


    • Rated Frequency (f):

    • Auxiliary Circuit 50 / 60 Hz
      Control Circuit 50 / 60 Hz


    • Conventional Free-air Thermal Current (Ith):

    • acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A
      acc. to IEC 60947-5-1, Θ = 40 °C 16 A


    • Rated Operational Current AC-1 (Ie):

    • (690 V) 40 °C 30 A
      (690 V) 55 °C 27 A
      (690 V) 70 °C 23 A


    • Rated Operational Current AC-3 (Ie):

    • (415 V) 55 °C 17 A
      (440 V) 55 °C 16 A
      (500 V) 55 °C 14 A
      (690 V) 55 °C 10 A
      (380 / 400 V) 55 °C 17 A
      (220 / 230 / 240 V) 55 °C 17


    • Rated Operational Power AC-3 (Pe):

    • (415 V) 9 kW
      (440 V) 9 kW
      (500 V) 9 kW
      (690 V) 9 kW
      (380 / 400 V) 7.5 kW
      (220 / 230 / 240 V) 4 kW


    • Rated Operational Power AC-6b (Pe):

    • (230 / 240 V) 40 °C, 50 / 60 Hz 7.5 kvar
      (230 / 240 V) 55 °C, 50 / 60 Hz 7.5 kvar
      (230 / 240 V) 70 °C, 50 / 60 Hz 6 kvar
      (400 / 415 V) 40 °C, 50 / 60 Hz 12.5 kvar
      (400 / 415 V) 70 °C, 50 / 60 Hz 10 kvar
      (400 / 415 V) 55 °C, 50 / 60 Hz 12.5 kvar
      (440 V) 40 °C, 50 / 60 Hz 14 kvar
      (440 V) 55 °C, 50 / 60 Hz 14 kvar
      (440 V) 70 °C, 50 / 60 Hz 10.5 kvar
      (500 / 550 V), 40 °C, 50 / 60 Hz 15.5 kvar
      (500 / 550 V) 55 °C, 50 / 60 Hz 15.5 kvar
      (500 / 550 V) 70 °C, 50 / 60 Hz 12 kvar
      (690 V) 40 °C, 50 / 60 Hz 21.5 kvar
      (690 V) 55 °C, 50 / 60 Hz 21.5 kvar
      (690 V) 70 °C, 50 / 60 Hz 16.5 kvar


    • Rated Breaking Capacity AC-3:

    • 8 x Ie AC-3


    • Rated Making Capacity AC-3:

    • 10 x Ie AC-3


    • Rated Operational Current AC-15 (Ie):

    • (500 V) 2 A
      (690 V) 2 A
      (24 / 127 V) 6 A
      (220 / 240 V) 4 A
      (380 / 400 V) 3 A


    • Short-Circuit Protective Devices:

    • Auxiliary Circuit - gG Type Fuses 10 A
      gG Type Fuses 32 A


    • Rated Short-time Withstand Current Low Voltage (Icw):

    • at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 140 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 30 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
      for 0.1 s 140 A
      for 1 s 100 A


    • Maximum Breaking Capacity:

    • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A


    • Maximum Electrical Switching Frequency:

    • (AC-1) 600 cycles per hour
      (AC-2 / AC-4) 300 cycles per hour
      (AC-3) 1200 cycles per hour


    • Rated Operational Current DC-13 (Ie):

    • (24 V) 6 / 144 A
      (48 V) 2.8 / 134 A
      (72 V) 2 / 144 W
      (125 V) 1.1 / 138 W
      (250 V) 0.55 / 138 W


    • Rated Insulation Voltage (Ui):

    • acc. to IEC 60947-4-1 1000 V
      acc. to IEC 60947-5-1 690 V
      acc. to UL/CSA 600 V


    • Rated Impulse Withstand Voltage (Uimp):

    • 8 kV


    • Maximum Mechanical Switching Frequency:

    • 3600 cycles per hour


    • Rated Control Circuit Voltage (Uc):

    • 50 Hz 220 ... 230 V
      60 Hz 230 ... 240 V


    • Coil Consumption:

    • Average Holding Value 50 / 60 Hz 8 V·A
      Average Pull-in Value 50 Hz 74 V·A
      Average Pull-in Value 60 Hz 70 V·A


    • Operate Time:

    • Between Coil De-energization and NO Contact Opening 4 ... 11 ms
      Between Coil Energization and NO Contact Closing 10 ... 26 ms


    • Mounting on DIN Rail:

    • TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
      TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715


    • Mounting by Screws (not supplied):

    • 2 x M4 screws placed diagonally


    • Connecting Capacity Main Circuit:

    • Flexible with Cable End 0.75 ... 2.5 mm²
      Rigid Cable 1 ... 4 mm²


    • Connecting Capacity Auxiliary Circuit:

    • Flexible with Cable End 0.75 ... 2.5 mm²
      Rigid Cable 1 ... 4 mm²