| With display | No |
|---|---|
| Voltage type for actuating | AC/DC |
| Rated operating voltage Ue | 200 V |
| Rated control supply voltage at AC 50 Hz | 100 V |
| Rated control supply voltage at AC 60 Hz | 100 V |
| Fan power rating | 20 VA |
| Overload current | 27 A |
| Controller type | SMC-3 |
| DV/DT protection | 1000V/µs for power circuit |
| Repetitive peak voltage | 1400V per UL/CSA/NEMA for power circuit |
| Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit |
| Line connected motor power, max | 55 kW @ 380/400/415V AC, 50 Hz, 3-phase |
| Delta connected motor power, max | 90 kW @ 380/400/415V AC, 50 Hz, 3-phase |
| Overvoltage category | III per IEC for side mount auxiliary contacts |
| Rated impulse voltage | 6 kV for power circuit |
| Dielectric withstand | 2500V AC per IEC for power circuit |
| Line connected motor current | 27...108 A @ 380/400/415/460V AC, 3-phase |
| Delta connected motor current | 47...187 A @ 380/400/415/460V AC, 3-phase |
| Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit |
| Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
| Rated control power during start with fan | 200 mA @ 120V AC/120 mA @ 240V AC, 600 mA @ 24V AC/DC |
| Input OFF-state current | <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit |
| Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
| Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
| High capacity available fault current, max | 70 kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors |
| Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
| Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
| Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
| Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
| Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
| Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6 A @ 120V AC and 0.3 A @ 240V AC for auxiliary contacts |
| Standard controller feature | Soft stop |
| Standard available fault current, max | 10 kA @ maximum standard fuse 600 A for delta device operational current rating |